Intel® Workstation Board S5520SC TPS Functional Architecture
Revision 1.7
Intel order number: E39530-010
39
PCI Bus Segment Voltage Width Speed Type PCI I/O Card Slots
PE5
ICH10R PCI
Express* Port
3.3 V X1 2.5 Gb/s PCI
Express*
Gen1
x1 PCI Express* Gen1 throughput to
onboard Integrated BMC
PE6
ICH10R PCI
Express* Port
3.3 V X1 2.5 Gb/s PCI
Express*
Gen1
x1 PCI Express* Gen 1 throughput to Slot 3
(x4 Mechanically)
PE1, PE2
5520 IOH PCI
Express* Ports
3.3 V x4 10 Gb/s PCI
Express*
Gen1
x4 PCI Express* Gen1 throughput to
onboard NIC (82575EB)
PE3, PE4, PE5, PE6
5520 IOH PCI
Express* Ports
3.3 V X16 80 Gb/S PCI
Express*
Gen2
x16 PCI Express* Gen2 throughput to Slot 6
(x16 Mechanically)
PE7, PE8, PE9,
PE10
5520 IOH PCI
Express* Ports
3.3 V X16 80 Gb/S PCI
Express*
Gen2
x16 PCI Express* Gen2 throughput to Slot 4
(x16 Mechanically)
3.6 Intel
®
SAS Entry RAID Module AXX4SASMOD (Accessory)
The Intel
®
Workstation Board provides a Serial Attached SCSI (SAS) module slot (J2J1) for the
installation of an optional Intel
®
SAS Entry RAID Module AXX4SASMOD. Once the optional
Intel
®
SAS Entry RAID Module AXX4SASMOD is detected, the x4 PCI Express* links from the
ICH10R to Slot 2 (x8 mechanically, x4 electrically) switches to the SAS module slot.
The Intel
®
SAS Entry RAID Module AXX4SASMOD includes a SAS1064e controller that
supports x4 PCI Express* link widths and is a single-function PCI Express* end-point device.
The SAS controller supports the SAS protocol as described in the Serial Attached SCSI
Standard, version 1.0, and also supports SAS 1.1 features. A 32-bit external memory bus off the
SAS1064e controller provides an interface for Flash ROM and NVSRAM (Non-volatile Static
Random Access Memory) devices.
The Intel
®
SAS Entry RAID Module AXX4SASMOD provides four SAS connectors that support
up to four hard drives with a non-expander backplane or up to eight hard drives with an
expander backplane.
The Intel
®
SAS Entry RAID Module AXX4SASMOD also provides a SGPIO (Serial General
Purpose Input/Output) connector and a SCSI Enclosure Services (SES) connector for
backplane drive LED control.
Warning!: Either the SGPIO or the SES connector supports backplane drive LED control. Do
not connect both SGPIO and SES connectors at the same time.