Intel
®
Server Board SHG2
Product Guide
A Guide for Technically Qualified Assemblers of Intel
®
Identified
Subassemblies/Products
Order Number: A90327-003
Zobrazit stránku 0
1 2 3 4 5 6 ... 99 100

Shrnutí obsahu

Strany 1 - Product Guide

Intel® Server Board SHG2 Product Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Order Number: A9

Strany 2 - Disclaimer

10 Intel Server Board SHG2 Product Guide Back Panel Connectors OM14358NIC2(Gbit)NIC1(10/100)ABC EDFG HJKI A AC Power* G Video B USB 1, 2, 3

Strany 3 - Contents

100 Intel Server Board SHG2 Product Guide V-W video blanking for security, 20 memory, 9 video controller, 9, 13 Warning components may be hot, 45, 52

Strany 4 - 3 Upgrading

Description 11 Server Board Connector and Component Locations ABCDEFGHIJKLMNOPQRSTUVXWYZAABBCCDDEEFFGGHHII JJ KKLLOM14357 A Primary Processor Socket

Strany 5 - 7 Technical Reference

12 Intel Server Board SHG2 Product Guide Processor The Intel® Server Board SHG2 supports one or two Intel Xeon processors from 1.8 GHz to 2.4 GHz, wi

Strany 6 - Figures

Description 13 Add-in Board Connectors The server board has the following add-in board connectors: • Two 184-pin full-length, 3.3 V, PCI-X 64-bit/10

Strany 7 - Contents vii

14 Intel Server Board SHG2 Product Guide SCSI Controller The embedded Adaptec AIC-7899W dual function SCSI controller provides Ultra160 (LVDS), (Ultr

Strany 8

Description 15 Network Controllers The server board includes two integrated onboard Network Interface Controllers (NICs). One NIC is a 10BASE-T/100BA

Strany 9 - 1 Description

16 Intel Server Board SHG2 Product Guide Adapter Fault Tolerance Adapter Fault Tolerance (AFT) is a simple, effective, and fail-safe approach to incr

Strany 10 - Back Panel Connectors

Description 17 Keyboard and Mouse The keyboard/mouse controller is PS/2-compatible. If specified through the System Setup Utility (SSU), the server

Strany 11

18 Intel Server Board SHG2 Product Guide Software Locks The BIOS Setup and the System Setup Utility (SSU) provide a number of security features to pr

Strany 12 - Processor

Description 19 Secure Mode Configure and enable the secure boot mode by using the SSU. When secure mode is in effect: • You can boot the server and

Strany 13 - Add-in Board Connectors

Disclaimer Information in this document is provided in connection with Intel® products. No license, express or implied, by est

Strany 14 - IDE Controller

20 Intel Server Board SHG2 Product Guide Table 3. Software Security Features (continued) Feature Description Set a time-out period so that keyboard

Strany 15 - Network Controllers

21 2 Server Board Installation Tools and Supplies Needed • Phillips† (cross head) screwdriver (#1 bit and #2 bit) • Flat blade screwdriver • Antis

Strany 16 - Adaptive Load Balancing

22 Intel Server Board SHG2 Product Guide Safety and Regulatory Compliance See “Regulatory and Integration Information” on page 91 for product Safety

Strany 17 - Security

Server Board installation 23 Installation Notes Installation Process Quick Reference Step Where the information is located Install the primary pro

Strany 18 - Software Locks

24 Intel Server Board SHG2 Product Guide Attaching the Gasket to the I/O Shield 1. Remove the two backing strips from the gasket. 2. Press the gask

Strany 19 - Secure Mode

Server Board installation 25 Installing the I/O Shield 1. Position one edge so that the dotted groove is outside the chassis wall, and the lip of

Strany 20

26 Intel Server Board SHG2 Product Guide Installing Memory The SHG2 Server Board contains six 184-pin DIMM sockets. Memory is partitioned as three b

Strany 21 - 2 Server Board Installation

Server Board installation 27 1. If the server board is not already installed in the chassis, remove the server board from its packaging and place

Strany 22 - Power Supply

28 Intel Server Board SHG2 Product Guide Installing the Server Board 1. Place the board into the chassis, making sure that the back panel I/O shield

Strany 23 - Installation Procedures

Server Board installation 29 Installing the Processor(s) CAUTIONS If only one processor is to be used, it must be installed in the Processor Socke

Strany 24 - PARALLEL

iii Contents 1 Description Server Board Features ...

Strany 25 - Installing the I/O Shield

30 Intel Server Board SHG2 Product Guide 3. Lift the socket lever on the processor socket labeled CPU1. (If adding a second processor, lift the soc

Strany 26 - Installing Memory

Server Board installation 31 5. Apply thermal grease to the processor as shown. OM14366 Figure 12. Applying Thermal Grease 6. Align the heat sin

Strany 27 - Figure 7. Installing Memory

32 Intel Server Board SHG2 Product Guide 7. Position the retention clip over the plastic tab and engage the retention clip end-slot over the plastic

Strany 28 - Installing the Server Board

Server Board installation 33 1. Install processor wind tunnel center section over the heat sink / processor assembly. Note that plastic tabs on t

Strany 29 - Installing the Processor(s)

34 Intel Server Board SHG2 Product Guide 3. Attach the air intake fan assembly to the side of the heat sink wind tunnel closest to the front of the

Strany 30 - A. Alignment Triangle Mark

Server Board installation 35 Making Connections to the Server Board ABCDEFGHIJKLMNOPQRSTUVXWYZAABBCCDDEEFFGGHHII JJ KKLLOM14357 A. Primary Process

Strany 31

36 Intel Server Board SHG2 Product Guide Intel® SC5200 Base Server Chassis Note Connect front system fans to the System Fan 3 and System Fan 5 connec

Strany 32

Server Board installation 37 Floppy and Front Panel Cables Route the floppy drive and front panel cables as shown. ABOM14376 A. Front Panel Cable

Strany 33 - Fan label

38 Intel Server Board SHG2 Product Guide Installing the Serial B Cable For the Intel SC5200 chassis, you can connect the Serial B serial port cable t

Strany 34

Server Board installation 39 Finishing Up WARNING An electrical shock hazard exists if the chassis cover is not replaced before connecting the cha

Strany 35

iv Intel Server Board SHG2 Product Guide 3 Upgrading Tools and Supplies Needed...

Strany 36 - IDE or SCSI Cables

40 Intel Server Board SHG2 Product Guide Getting Started with Intel® Server Management and Intel® SMaRT Tool (Optional) Intel® Server Management and

Strany 37 - Chassis

Server Board installation 41 Installing your Operating System Install your operating system now. Installing Intel Server Management You can install

Strany 38 - B. Screw

42 Intel Server Board SHG2 Product Guide Installing Intel SMaRT Tool Follow the instructions below to install the Intel Server Maintenance and Refere

Strany 39 - Finishing Up

43 3 Upgrading Tools and Supplies Needed • Phillips (cross head) screwdriver (#1 bit and #2 bit) • Antistatic wrist strap and conductive foam pad (r

Strany 40 - Tool (Optional)

44 Intel Server Board SHG2 Product Guide Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper p

Strany 41

Upgrading 45 1. Open both DIMM socket levers. 2. Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. 3. Chec

Strany 42 - Installing Intel SMaRT Tool

46 Intel Server Board SHG2 Product Guide Adding or Replacing a Processor If you are adding a second processor to your system, the second processor

Strany 43 - 3 Upgrading

Upgrading 47 5. Lift the socket lever on the processor socket labeled CPU1. (If adding a second processor, lift the socket lever on the process

Strany 44

48 Intel Server Board SHG2 Product Guide 7. Apply thermal grease to the processor as shown. OM14366 Figure 29. Applying Thermal Grease 8. Align t

Strany 45 - Processors

Upgrading 49 9. Position the retention clip over the plastic tab and engage the retention clip end-slot over the plastic tab (see 1 in Figure 31

Strany 46

Contents v 5 Solving Problems Resetting the System ...

Strany 47 - C. Alignment Triangle Mark

50 Intel Server Board SHG2 Product Guide 2. Attach the processor wind tunnel fan to the wind tunnel air intake assembly as shown. The fan label m

Strany 48

Upgrading 51 3. Attach the air intake fan assembly to the side of the heat sink wind tunnel closest to the front of the chassis. a. Press both s

Strany 49 - Upgrading 49

52 Intel Server Board SHG2 Product Guide Removing a Processor 1. Observe the safety and ESD precautions at the beginning of this chapter and the a

Strany 50

Upgrading 53 1. Observe the safety and ESD precautions at the beginning of this chapter. 2. Open the chassis. 3. Insert the tip of a small fla

Strany 51 - Upgrading 51

54 Intel Server Board SHG2 Product Guide

Strany 52 - Replacing the Backup Battery

55 4 Configuration Software and Utilities This chapter describes the Power-On Self-Test (POST) and server configuration utilities. The table below b

Strany 53 - Upgrading 53

56 Intel Server Board SHG2 Product Guide Power-On Self-Test (POST) Each time you turn on the system, POST starts running. POST checks the server bo

Strany 54

Configuration Software and Utilities 57 Using BIOS Setup This section describes the BIOS Setup options. Use Setup to change the server configurati

Strany 55 - Hot Keys

58 Intel Server Board SHG2 Product Guide Using the System Setup Utility The System Setup Utility (SSU) is located on the Intel Server Board SHG2 Res

Strany 56 - Power-On Self-Test (POST)

Configuration Software and Utilities 59 Running the SSU When the SSU starts in the default local execution mode, the SSU accepts input from the key

Strany 57 - Using BIOS Setup

vi Intel Server Board SHG2 Product Guide 9 Equipment Log Worksheet Equipment Log ...

Strany 58 - Creating SSU Diskettes

60 Intel Server Board SHG2 Product Guide Customizing the SSU Interface The SSU lets you customize your interface using the Preferences section of th

Strany 59 - Running the SSU

Configuration Software and Utilities 61 Setting the Admin Password The Admin Password button lets you set or change the admin password used by both

Strany 60 - Setting Boot Device Priority

62 Intel Server Board SHG2 Product Guide Viewing the System Event Log To view the System Event Log (SEL): 1. From the SSU Main window, choose SEL M

Strany 61 - Setting Security Options

Configuration Software and Utilities 63 Viewing Sensor Data Records To view the Sensor Data Records (SDR): 1. From the SSU Main window, choose SDR

Strany 62 - Viewing FRU Information

64 Intel Server Board SHG2 Product Guide Updating the Firmware To update the system firmware: 1. Download the update from the Intel support website

Strany 63 - Viewing Sensor Data Records

Configuration Software and Utilities 65 Restoring a Configuration To restore the system configuration from a file: 1. From the SSU Main window, ch

Strany 64 - Saving a Configuration

66 Intel Server Board SHG2 Product Guide 5. Click Save to save the changes. 6. Click Close to return to the PEM window. 7. In the PEM window, click

Strany 65 - Alerting for Platform Events

Configuration Software and Utilities 67 7. If you chose Static IP Setup in the previous step, fill in the IP addressing boxes: • Host IP Address:

Strany 66 - Setting Up LAN Alerts

68 Intel Server Board SHG2 Product Guide • Restricted: a remote system can initiate a LAN connection, but cannot perform control operations such a

Strany 67 - Managing the Server Remotely

Configuration Software and Utilities 69 8. From the Connection Mode list, choose either: • Direct Connect: the COM2 port on the server is connect

Strany 68

Contents vii Tables 1. Server Board Features... 9 2.

Strany 69 - FRUSDR Load Utility

70 Intel Server Board SHG2 Product Guide How You Use the FRUSDR Load Utility This utility is compatible with ROM-DOS Ver. 6.22, MS-DOS† Ver. 6.22, a

Strany 70 - Displaying a Given Area

Configuration Software and Utilities 71 Displaying SM BIOS Area The SM BIOS area is displayed in ASCII format when the field is ASCII or as a numbe

Strany 71 - Using Specified CFG File

72 Intel Server Board SHG2 Product Guide Updating the SDR Nonvolatile Storage Area After the utility validates the header area of the supplied SDR f

Strany 72

Configuration Software and Utilities 73 Upgrading the BIOS Preparing for the Upgrade Before you upgrade the BIOS, prepare for the upgrade by record

Strany 73 - Upgrading the BIOS

74 Intel Server Board SHG2 Product Guide Creating the BIOS Upgrade Diskette The BIOS upgrade file is a compressed self-extracting archive that conta

Strany 74

Configuration Software and Utilities 75 Recovering the BIOS It is unlikely that anything will interrupt the BIOS upgrade; however, if an interrupti

Strany 75 - Changing the BIOS Language

76 Intel Server Board SHG2 Product Guide Using the Firmware Update Utility The Firmware Update Utility is a DOS-based program used to update the Bas

Strany 76 - Updating the BMC Firmware

Configuration Software and Utilities 77 Recovering the BMC Firmware In the event of BMC Firmware corruption, the following procedure may be used to

Strany 77 - Updating the FRU/SDR Files

78 Intel Server Board SHG2 Product Guide Using the Adaptec SCSI Utility The Adaptec SCSI utility detects the SCSI host adapters on the server board.

Strany 78 - Running the SCSI Utility

79 5 Solving Problems This chapter helps you identify and solve problems that might occur while you are using the system. Resetting the System To do t

Strany 79 - 5 Solving Problems

viii Intel Server Board SHG2 Product Guide

Strany 80 - Checklist

80 Intel Server Board SHG2 Product Guide Running New Application Software Problems that occur when you run new application software are usually rela

Strany 81 - Monitoring POST

Solving Problems 81 More Problem Solving Procedures This section provides a more detailed approach to identifying a problem and locating its source

Strany 82 - Power Light Does Not Light

82 Intel Server Board SHG2 Product Guide Verifying Proper Operation of Key System Lights As POST determines the system configuration, it tests for t

Strany 83 - Solving Problems 83

Solving Problems 83 No Characters Appear on Screen Check the following: q Is the keyboard functioning? Check to see that the “Num Lock” light is f

Strany 84

84 Intel Server Board SHG2 Product Guide System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, system co

Strany 85 - Problems with Network

Solving Problems 85 CD-ROM Drive Activity Light Does Not Light Check the following: q Are the CD-ROM drive’s power and signal cables properly insta

Strany 86 - PCI Installation Tips

86 Intel Server Board SHG2 Product Guide PCI Installation Tips Some common PCI tips are listed here. q Certain drivers may require interrupts that a

Strany 87 - 6 Getting Help

87 6 Getting Help World Wide Web http://support.intel.com/support/motherboards/server/SHG2 Telephone All calls are billed US $25.00 per incident, levi

Strany 88

88 Intel Server Board SHG2 Product Guide

Strany 89 - 7 Technical Reference

89 7 Technical Reference Server Board Jumpers OM14373CN271234128710943651211CN434123CN53 Figure 37. Jumper Locations Table 7. Configuration Jumper

Strany 90

9 1 Description Server Board Features Table 1. Server Board Features Feature Description Processor Up to two 1.8 GHz to 2.4 GHz Intel® Xeon™ processo

Strany 91 - Product EMC Compliance

90 Intel Server Board SHG2 Product Guide Table 8. Configuration Jumper (CN27) Jumper Name Pins What it does at system reset BIOS Write Protect 1

Strany 92

91 8 Regulatory and Integration Information Product Regulatory Compliance Product Safety Compliance The SHG2 complies with the following safety requi

Strany 93 - FCC (USA)

92 Intel Server Board SHG2 Product Guide Product Regulatory Compliance Markings This product is marked with the following Product Certification Marki

Strany 94 - Australia / New Zealand

Regulatory and Integration Information 93 Electromagnetic Compatibility Notices FCC (USA) This device complies with Part 15 of the FCC Rules. Oper

Strany 95

94 Intel Server Board SHG2 Product Guide INDUSTRY CANADA (ICES-003) This digital apparatus does not exceed the Class A limits for radio noise emissio

Strany 96 - Equipment Log (continued)

95 9 Equipment Log Worksheet Equipment Log Use the blank equipment log provided here to record information about your system. You will need some of

Strany 97 - Index 97

96 Intel Server Board SHG2 Product Guide Equipment Log (continued) Item Manufacturer Name and Model Number Serial Number Date Installed

Strany 98 - 98 Intel

Index 97 Index A Adapter Fault Tolerance, 15, 16 Adaptive Load Balancing, 15, 16 Add-in boards add-in board connectors, 13 PCI-X, 13 administrative p

Strany 99 - Index 99

98 Intel Server Board SHG2 Product Guide F fan, heat sink, disconnecting, 46, 52 Fast EtherChannel, 15 feature summary back panel connectors, 10 boar

Strany 100 - 100 Intel

Index 99 processor, 52 adding, 46 removing, 46, 52 selecting the correct processor, 45, 52 wind tunnel installation, 49 R RAIDIOS, 14 real time clock