Intel R1304BTSSFAN Datový list Strana 51

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 67
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 50
Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
Appendix B: Integrated BMC Sensor Tables
Revision 2.0 43
Intel order number G17455-004
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset Triggers Contrib. To
System Status
Assert/De-
assert
Readable
Value/Off
sets
Event
Data
Rearm Stand-by
System Event
(System Event)
08h All
System
Event
12h
Sensor Specific
6Fh
04 – PEF action
OK As _
Trig
Offset
A X
Button Sensor
(Button)
09h All
Button/Switc
h
14h
Sensor Specific
6Fh
00 – Power Button
02 – Reset Button
OK AS _
Trig
Offset
A X
PCH Thermal Trip
(PCH Therm Trip)
0Dh All
Temperature
01h
Digital Discrete
03h
01 – State Asserted Fatal
As and
De
Trig
Offset
M X
Baseboard
Temperature 1
(Baseboard Temp)
20h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Front Panel
Temperature
(Front Panel Temp)
21h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
PCH
TemperatureNote1
(PCH Temp)
22h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Baseboard
Temperature 3
(Inlet Temp)
24h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Hot-swap Backplane
Temperature
(HSBP Temp)
29h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Zobrazit stránku 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 66 67

Komentáře k této Příručce

Žádné komentáře