Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
Appendix B: Integrated BMC Sensor Tables
Revision 2.0 41
Intel order number G17455-004
Table 31. BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset Triggers Contrib. To
System Status
Assert/De-
assert
Readable
Value/Off
sets
Event
Data
Rearm Stand-by
Power Unit Status
(Pwr Unit Status)
01h All
Power Unit
09h
Sensor Specific
6Fh
00 - Power down
OK
As and
De
Trig
Offset
A X
04 - A/C lost
05 - Soft power control
failure
Fatal
06 - Power unit failure
Power Unit
Redundancy1
(Pwr Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully Redundant OK
As and
De
Trig
Offset
A X
01 - Redundancy lost Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degraded
04 – Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degraded
05 - Non-redundant:
insufficient resources
Fatal
06 – Redundant:
degraded from fully
redundant state.
Degraded