Intel R1304BTSSFAN Datový list Strana 57

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 67
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 56
Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
Appendix B: Integrated BMC Sensor Tables
Revision 2.0 49
Intel order number G17455-004
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset Triggers Contrib. To
System Status
Assert/De-
assert
Readable
Value/Off
sets
Event
Data
Rearm Stand-by
Baseboard +1.5V
Auxiliary
(BB +1.5V AUX)
E9h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Hard Disk Drive 0
Status
(HDD 0 Status)
F0h
Chassis-
specific
Drive Slot
0Dh
Sensor Specific
6Fh
00 - Drive Presence OK
As and
De
Trig
Offset
A X
01- Drive Fault Degraded
02- Predictive Failure Degraded
07 - Rebuild/Remap in
progress
Degraded
Hard Disk Drive 1
Status
(HDD 1 Status)
F1h
Chassis-
specific
Drive Slot
0Dh
Sensor Specific
6Fh
00 - Drive Presence OK
As and
De
Trig
Offset
A X
01- Drive Fault Degraded
02- Predictive Failure Degraded
07 - Rebuild/Remap in
progress
Degraded
Hard Disk Drive 2
Status
(HDD 2 Status)
F2h
Chassis-
specific
Drive Slot
0Dh
Sensor Specific
6Fh
00 - Drive Presence OK
As and
De
Trig
Offset
A X
01- Drive Fault Degraded
02- Predictive Failure Degraded
07 - Rebuild/Remap in
progress
Degraded
Hard Disk Drive 3
Status
F3h
Chassis-
specific
Drive Slot Sensor Specific
00 - Drive Presence OK
As and
De
Trig
Offset
A
01- Drive Fault Degraded
Zobrazit stránku 56