Table 6. Quality of Service
Quality of Service
3, 4
(99.9%)
Quality of Service
3,4
(99.9999%)
Notes:
1. Device measured using Iometer. Latency measured using 4 KB (4,096 bytes) transfer size with Queue Depth equal to 1 on a
sequential workload.
2. Power On To Ready time assumes proper shutdown. Time varies if shutdown is not preceded by STANDBY IMMEDIATE command.
3. Device measured using Iometer. Quality of Service measured using 4 KB (4,096 bytes) transfer size on a random workload on a
full Logical Block Address (LBA) span of the drive once the workload has reached steady state but including all background
activities required for normal operation and data reliability.
4. Based on Random 4KB QD=1, 32 workloads, measured as the time taken for 99.9(or 99.9999) percentile of commands to finish
the round-trip from host to drive and back to host.
2.3 Electrical Characteristics
Table 7. Operating Voltage for 2.5-inch Form Factor
Electrical Characteristics
80 GB, 120 GB, 160 GB, 240 GB, 300 GB, 480 GB, 600 GB, 800 GB
5 V Operating Characteristics:
Operating Voltage range
Rise time (Max/Min)
Fall time (Min)
Noise level
Min Off time
Inrush Current (Typical Peak)
1
5 V (±5%)
1 s / 1 ms
1 ms
500 mV pp 10 Hz – 100 KHz
50 mV pp 100 KHz – 20 MHz
500 ms
1.0 A, < 1 s
12 V Operating Characteristics:
Operating Voltage range
Rise time (Max/Min)
Fall time (Min)
Noise level
Min Off time
Inrush Current (Typical Peak)
1
12 V (±10%)
1 s / 1 ms
1 ms
1000 mV pp 10 Hz – 100 KHz
100 mV pp 100 KHz – 20 MHz
500 ms
1.0 A, < 1 s
Notes:
1. Measured from initial device power supply application.