26 MPCMM0001 Chassis Management Module Software Technical Product Specification
Redundancy, Synchronization, and Failover
There is Priority 2 data to sync.
No Data Synchronization problems known.
Initial Data Synch Incomplete, Pri 1 Data Synced, Pri 2 Data Not Synched
The current value is 0x0003
Initial Data Synchronization is not complete.
Priority 1 data is synced.
There is Priority 2 data to sync.
No Data Synchronization problems known.
Initial Data Sync is complete, Priority 1 and Priority 2 are also synced
The current value is 0x000f
Initial Data Synchronization is complete.
Priority 1 data is synced.
Priority 2 data is synced.
No Data Synchronization problems known.
Initial Data Sync failure
The current value is 0x0013
Initial Data Synchronization is not complete.
Priority 1 data is synced.
There is Priority 2 data to sync.
Data Synchronization has encountered a problem in synchronizing data.
Initial Data Sync is complete and Priority 1 data is changed
The current value is 0x000d
Initial Data Synchronization is complete.
There is Priority 1 data to sync.
Priority 2 data is synced.
No Data Synchronization problems known
Data Sync failure of Priority 1 Data occurs after Initial Data Sync and there is a Data Sync
Problem
The current value is 0x001d
Initial Data Synchronization is complete.
There is Priority 1 data to sync