Intel Sx220 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Servery Intel Sx220. Intel SX220 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 150
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User Guide

Viglen SX220 User Guide – MA-SX220-0A-01 User Guide®®C O M P U T E R S N E T W O R K S S O L U T I O N SMindsT h i n kG r

Strany 2 - 1. Overview 5

Viglen SX220 User Guide 9Chassis Back I/O Ports and Features The back panel provides connectors for the server board, slots for add-in cards, and th

Strany 3 - Viglen SX220 User Guide 2

Viglen SX220 User Guide 996. Insert the bootable diskette into drive A. 7. To extract the BIOS.EXE file to the diskette, change to the temporary d

Strany 4 - Viglen SX220 User Guide 3

Viglen SX220 User Guide 100 5. Reinstall the access cover and connect the power cord. 6. Insert the diskette holding the BIOS upgrade and recovery

Strany 5 - Viglen SX220 User Guide 4

Viglen SX220 User Guide 1017. The program will load the file and then ask if it should upload boot code. Press “N” to continue unless otherwise dir

Strany 6 - Introduction

Viglen SX220 User Guide 102 • Is compatible with ROM-DOS Ver. 6.22, MS-DOS Ver. 6.22 (and later versions), Windows 95 DOS, and Windows 98 DOS • Acc

Strany 7 - Viglen SX220 User Guide 6

Viglen SX220 User Guide 103specified CFG file and uses the entries in that file to probe the hardware and to select the proper SDRs to load into non-

Strany 8 - Physical Specifications

Viglen SX220 User Guide 104 77.. IInntteell SSeerrvveerr CCoonnttrrooll Legal Information from software supplier An Intel ® product, when use

Strany 9

Viglen SX220 User Guide 105About Intel Server Control NOTE: This section describes the Intel Server Control (ISC) server-management package. Intr

Strany 10

Viglen SX220 User Guide 106 be used to validate and isolate problems in the server. The tests are controlled via a text-based console redirected to th

Strany 11 - Security

Viglen SX220 User Guide 107The next table shows the typical tasks that a system administrator might do. They include normal system administration, se

Strany 12 - Optional Peripherals

Viglen SX220 User Guide 108 of the software on the same server. It is also possible to install Platform Instrumentation on multiple servers and Consol

Strany 13 - Server Board Features

Viglen SX220 User Guide 10 Power Supply The power supply consists of the power supply bay and one power supply module. A second power supply module c

Strany 14 - Viglen SX220 User Guide 13

Viglen SX220 User Guide 109• Manage non-Intel-based systems via the Intelligent Chassis Management Bus (ICMB). • Remotely monitor server hardware

Strany 15 - Back Panel Connectors

Viglen SX220 User Guide 110 Since DPC does not communicate with the server-resident operating system, it can be used to manage the server even if the

Strany 16 - Viglen SX220 User Guide 15

Viglen SX220 User Guide 111• Configuration registers The Client SSU stores configuration values in flash memory. These values take effect when you

Strany 17 - IDE Controller

Viglen SX220 User Guide 112 The DMI Explorer can be installed as a tool available from the ISC Console. Select “Install DMI Explorer” when you are ins

Strany 18 - Network Teaming Features

Viglen SX220 User Guide 113OpenView The HP OpenView Network Node Manager Console automatically detects servers running the ISC Platform Instrumentat

Strany 19 - Preferred Primary Adapter

Viglen SX220 User Guide 114 Using the modem connection via the Direct Platform Control (DPC), you can: • Reset the remote server’s power. • Reboot

Strany 20 - RJ-45 Serial Port

Viglen SX220 User Guide 115Setting Up an ICMB Connection An ICMB connection requires: • A managed server with an ICMB interface. • A server with

Strany 21

Viglen SX220 User Guide 116 further analyse the condition of the server. Pages can be configured for the following events: • Temperature Sensor out

Strany 22

Viglen SX220 User Guide 117Intel Server Control Console Main Screen The following figure shows the Intel Server Control Console. Figure 48: Intel

Strany 23 - Viglen SX220 User Guide 22

Viglen SX220 User Guide 118 Server Menu Options Discover You can discover multiple servers in a single step and add them to the server tree. Servers

Strany 24 - Viglen SX220 User Guide 23

Viglen SX220 User Guide 11of the system, some 2-post relay racks may not, causing the racks to fail. Only use relay racks that are specifically desig

Strany 25 - Viglen SX220 User Guide 24

Viglen SX220 User Guide 1194. Click OK. The ISC Console will test the specified server for all ISC-registered tools. If one or more of the tools is

Strany 26

Viglen SX220 User Guide 120 The Status Bar The status bar displays information about ISC Console operations, such as the number of servers found with

Strany 27 - Before You Begin!

Viglen SX220 User Guide 12188.. SSoollvviinngg PPrroobblleemmss The first part of this chapter helps you identify and solve problems that might o

Strany 28 - Viglen SX220 User Guide 27

Viglen SX220 User Guide 122  Are all DIMMs installed correctly?  Are all peripheral devices installed correctly?  If the system has a hard disk

Strany 29 - Installing the Server Board

Viglen SX220 User Guide 123 If you are running the software from a CD-ROM disk, try a different disk to see if the problem occurs on all disks. 

Strany 30

Viglen SX220 User Guide 124 5. Turn on the system. If the power LED does not light, see “Power Light Does Not Light” on page 125 6. If errors are

Strany 31

Viglen SX220 User Guide 125Try the solutions in the order given. If you cannot correct the problem, contact your service representative or authorise

Strany 32

Viglen SX220 User Guide 126 If the problem persists, the video monitor may be faulty or it may be the incorrect type. Contact your service represent

Strany 33 - Routing Cables

Viglen SX220 User Guide 127 Are all relevant switches and jumpers on the drive set correctly?  Is the drive properly configured?  Is the onboar

Strany 34

Viglen SX220 User Guide 128  Run the diagnostics. Problems with Application Software If you have problems with application software, do the follow

Strany 35 - Installing the Fan Assembly

Viglen SX220 User Guide 12 33.. MMootthheerrbbooaarrdd SSppeecciiffiiccaattiioonn Server Board Features Table 2: Server Board Features Feature D

Strany 36

Viglen SX220 User Guide 12999.. TTeecchhnniiccaall RReeffeerreennccee Server Board Jumpers Figure 49: Server Board Jumpers Table 40: Configura

Strany 37

Viglen SX220 User Guide 130 nibble is represented by a red LED and each bit in the lower nibble is represented by a green LED. If both bits are set i

Strany 38

Viglen SX220 User Guide 131Table 41 : POST Codes (Continued) Diagnostic LED Decoder G=Green, R=Red, A=Amber Post Code MSB LSB Description 19h G

Strany 39

Viglen SX220 User Guide 132 Table 41 : POST Codes (Continued) Diagnostic LED Decoder G=Green, R=Red, A=Amber Post Code MSB LSB Description 39h G

Strany 40

Viglen SX220 User Guide 133Table 41 : POST Codes (Continued) Diagnostic LED Decoder G=Green, R=Red, A=Amber Post Code MSB LSB Description 9Bh A Of

Strany 41

Viglen SX220 User Guide 134 1100.. RReegguullaattoorryy && IInntteeggrraattiioonn IInnffoorrmmaattiioonn Product Regulatory Compliance

Strany 42 - Installing Peripherals

Viglen SX220 User Guide 135• AS/NZS 3548 (Class A) – Radiated & Conducted Emissions (Australia / New Zealand) • RRL (Class A) Radiated & C

Strany 43

Viglen SX220 User Guide 136 BSMI (Taiwan) The BSMI Certification number 3902I904 is silk screened on the component side of the server board; and the

Strany 44

Viglen SX220 User Guide 1371111.. EEqquuiippmmeenntt LLoogg && PPoowweerr CCoonnssuummppttiioonn Equipment Log Use the blank equipme

Strany 45

Viglen SX220 User Guide 138 Table 42: Equipment Log (continued) Item Manufacturer Name and Model Number Serial Number Date Installed

Strany 46

Viglen SX220 User Guide 13Server Board Connector and Component Locations Figure 4: Server Board components A – Speaker R – CPU 1 fan connector B

Strany 47 - Viglen SX220 User Guide 46

Viglen SX220 User Guide 139Current Usage NOTE: Both processors pull power from +5V. This may limit the number of drives and/or add-in cards you may

Strany 48

Viglen SX220 User Guide 140 Worksheet, Calculating DC Power Usage 1. List the current for each board and device in the appropriate voltage level colu

Strany 49 - Viglen SX220 User Guide 48

Viglen SX220 User Guide 141Worksheet, Total Combined Power Used by the System 1. From the previous worksheet, enter the total current for each colum

Strany 50

Viglen SX220 User Guide 142 1122.. AAppppeennddiixx Contacting Viglen Viglen Technical Support Tel: 020 8758 7050 Fax: 020 8758 7097 E-mail

Strany 51

Viglen SX220 User Guide 1431133.. NNootteess

Strany 52

Viglen SX220 User Guide 144

Strany 53 - Removing the Rails

Viglen SX220 User Guide 145

Strany 54

Viglen SX220 User Guide 146 1144.. VViigglleenn,, EEMMCC aanndd tthhee ‘‘CCEE’’ mmaarrkk CE Marking As we begin the 21st century, European st

Strany 55

Viglen SX220 User Guide 1471155.. CCooppyyrriigghhttss aanndd TTrraaddeemmaarrkkss Please note The material in this manual is subject to chang

Strany 56 - Viglen SX220 User Guide 55

Viglen SX220 User Guide 148 1166.. SSuuggggeessttiioonnss Viglen is interested in continuing to improve the quality and information provided in th

Strany 57

Viglen SX220 User Guide 14 Back Panel Connectors Figure 5: Back Plane Connectors A – USB 1 connector G – NIC 1 RJ-45 connector B – Video connecto

Strany 58 - Hot Keys

Viglen SX220 User Guide 1495. How do you rate the Viglen Technical support and Service Departments?

Strany 59 - Power-On Self-Test (POST)

Viglen SX220 User Guide 15Processor The SCB2 motherboard accommodates one or two Intel Pentium III processors with 512k cache in the FC-PGA2 package

Strany 60 - Setup Menu

Viglen SX220 User Guide 16 Video The SCB2 motherboard uses an ATI RAGE XL PCI graphics accelerator with 8 MB of video SDRAM that supports all standar

Strany 61 - Main Menu

Viglen SX220 User Guide 17Network Controller NOTE: To ensure EMC product regulation compliance, the system must be used with a shielded LAN cable.

Strany 62 - Advanced Menu

Viglen SX220 User Guide 18 • Adaptive Load Balancing (ALB) - creates a team of 2 - 8 adapters to increase transmission throughput. Also includes AFT.

Strany 63

Viglen SX220 User Guide 1CCoonntteennttss 1. Overview 5 Introduction 5 2. Chassis Specifications 6 Chassis Specification

Strany 64

Viglen SX220 User Guide 19Mixed Adapter Teaming AFT supports up to eight server adapters per team, in any mix. Adaptive Load Balancing Adaptive Lo

Strany 65 - Security Menu

Viglen SX220 User Guide 20 The 8 pins of the RJ45 connector can be configured to match either of two pin-out standards used by serial port concentrato

Strany 66 - Server Menu

Viglen SX220 User Guide 21NOTE: The RJ45-to-DB9 adapter should match the configuration of the serial device used. One of two pin-out configurations a

Strany 67 - Boot Menu

Viglen SX220 User Guide 22 be configured through ISC to respond to an intrusion a number of ways, including powering down or locking the keyboard. So

Strany 68

Viglen SX220 User Guide 23• May enter the user password to enter BIOS Setup or the SSU. However, you will not be able to change many of the options.

Strany 69 - Exit Menu

Viglen SX220 User Guide 24 The server can boot and run the operating system, but mouse and keyboard input is not accepted until the user password is

Strany 70

Viglen SX220 User Guide 25Password menu of the User Password Option menu found in the Security Subsystem Group. To clear the password if you cannot

Strany 71 - Table 34: Exit Menu

Viglen SX220 User Guide 26 44.. AAsssseemmbblliinngg tthhee SSyysstteemm This chapter will give a step-by-step guide of installing the server boa

Strany 72 - Viglen SX220 User Guide 71

Viglen SX220 User Guide 27Warnings and Cautions! These warnings and cautions apply whenever you remove the access cover to access components inside

Strany 73 - Viglen SX220 User Guide 72

Viglen SX220 User Guide 28 Installing the Server Board Installing the server board consists of the following steps: • Removing the cover, Riser car

Strany 74 - Viglen SX220 User Guide 73

Viglen SX220 User Guide 2 Installing the Fan Assembly 34 Installing the Power Cord and Strain Relief Strap 35 Adding Components to the Se

Strany 75 - Viglen SX220 User Guide 74

Viglen SX220 User Guide 292. Lift straight up and remove it from the chassis. 3. Insert your finger in the plastic loop on riser card (B). 4. Pu

Strany 76 - Viglen SX220 User Guide 75

Viglen SX220 User Guide 30 Figure 10: Removing the Fan Assembly Installing the Server Board 1. Ensure that the Mylar insulator sheet is seated se

Strany 77 - Password Add-in

Viglen SX220 User Guide 31 Figure 11: Attaching the Server Board

Strany 78 - Options Button

Viglen SX220 User Guide 32 Routing Cables Figure 12: Routing Cables 1. Route the backplane power cable (A) from the power supply to the backplane

Strany 79 - SEL Manager Add-in

Viglen SX220 User Guide 335. Connect the end of the flex circuit cable (C) labeled to the floppy/front panel/IDE connector on the server board. Rout

Strany 80 - FRU Manager Add-in

Viglen SX220 User Guide 34 Installing the Fan Assembly CAUTION! When installing the fan assembly, avoid pinching cables routed in the area. 1. Ens

Strany 81 - Viglen SX220 User Guide 80

Viglen SX220 User Guide 35 Figure 14: System Fan Connectors 6. Connect the USB cable to the 10-pin USB connector on the server board (Figure 4, Po

Strany 82 - System Update Add-In

Viglen SX220 User Guide 36 Adding Components to the Server Board After installing the server board, you must add the desired number of processors and

Strany 83 - Viglen SX220 User Guide 82

Viglen SX220 User Guide 37 Figure 17: Inserting the Processor 7. Following the instructions packaged with the applicator, apply thermal grease to t

Strany 84 - Viglen SX220 User Guide 83

Viglen SX220 User Guide 38 Figure 18: Installing the Heatsink A. Heat sink retention clip B. Heat sink C. Socket and processor CAUTION! Use car

Strany 85 - Viglen SX220 User Guide 84

Viglen SX220 User Guide 3Software Updates 96 Software Update Package 96 Individual Updates 98 Upgrading the BIOS 99 Recove

Strany 86 - Viglen SX220 User Guide 85

Viglen SX220 User Guide 39 Figure 19: Locking Heatsink Lever 12. Install the fan on the processor heat sink making sure that it is seated flat on th

Strany 87 - Platform Event Paging Dialog

Viglen SX220 User Guide 40 Install the Processor Terminator If you are installing only one processor, you must install a terminator in the secondary

Strany 88 - BMC LAN-Configuration Dialog

Viglen SX220 User Guide 41 Figure 22: Installing DIMMs Installing Peripherals Peripherals and add-in cards are not included in your system and must

Strany 89 - Viglen SX220 User Guide 88

Viglen SX220 User Guide 42 3. Firmly push the PCI card connector into the riser card slot until it is fully seated. 4. Close the retainer clip (A).

Strany 90 - Viglen SX220 User Guide 89

Viglen SX220 User Guide 43 Figure 24: Installing a Riser Card Installing a Hard Drive The server can support up to seven hot swappable hard drives

Strany 91 - Platform Event Action Dialog

Viglen SX220 User Guide 44 Figure 25: Hard Drive Carrier 5. Remove the hard drive from its wrapper and place it on an anti-static surface. 6. Set

Strany 92 - Viglen SX220 User Guide 91

Viglen SX220 User Guide 4511. Reinstall a carrier/air baffle in any bays where you are not installing a carrier/drive. Installing a CD-ROM Drive/FDD

Strany 93 - Viglen SX220 User Guide 92

Viglen SX220 User Guide 46 NOTE: Using the legacy IDE connector on the SCB2 server board to support an IDE peripheral device in the SX220 server is no

Strany 94 - Viglen SX220 User Guide 93

Viglen SX220 User Guide 47CAUTION! Carefully route cables to minimise airflow blockage and cooling problems. Suggested Tape Drive Cabling A periph

Strany 95 - Exiting the SSU

Viglen SX220 User Guide 48 Figure 30: Onboard SCSI Connector Connecting to a SCSI Controller on a Full-height PCI Card 1. Obtain a SCSI cable with

Strany 96 - Platform Event Paging

Viglen SX220 User Guide 4 Current Usage 139 Calculating Power Consumption 139 Worksheet, Calculating DC Power Usage 140 Workshee

Strany 97 - Software Update Package

Viglen SX220 User Guide 49Connecting to a SCSI Controller on a Low Profile PCI Card 1. Obtain a SCSI cable with an unfolded length of 26-inches. 2

Strany 98 - Viglen SX220 User Guide 97

Viglen SX220 User Guide 50 Installing the Bezel Place the bezel between the chassis handles and push it toward the front of the chassis until it snap

Strany 99 - Individual Updates

Viglen SX220 User Guide 5155.. IInnssttaalllliinngg tthhee SSyysstteemm iinn aa RRaacckk CAUTION! ANCHOR THE EQUIPMENT RACK: The equipment r

Strany 100 - Recovering the BIOS

Viglen SX220 User Guide 52 Removing the Rails 1. Fully extend a rail assembly (Figure 35). The finger tab (D) for the extension lock is revealed. 2

Strany 101 - Viglen SX220 User Guide 100

Viglen SX220 User Guide 53 Figure 36: Attaching the Rails A. Inside rail B. #6-32 x 3/16-inch screw C. Attachment hole D. Attachment tab E. Attach

Strany 102 - Viglen SX220 User Guide 101

Viglen SX220 User Guide 54 Attach a Rail Assembly to a Front Bracket 1. Position a rail assembly (middle and outer rails) with its black plastic end

Strany 103 - Viglen SX220 User Guide 102

Viglen SX220 User Guide 55A. Front bracket B. Outer rail C. Screw hole D. Threaded hole E. Not Shown F. Access hole G. #6-32 x 3/16-inch screw Atta

Strany 104 - Viglen SX220 User Guide 103

Viglen SX220 User Guide 56 Figure 40: Rails Fully Extended CAUTION! Lifting and placing the chassis in the rails is a two-person job. If needed, u

Strany 105 - Viglen SX220 User Guide 104

Viglen SX220 User Guide 5766.. CCoonnffiigguurraattiioonn SSooffttwwaarree aanndd UUttiilliittyy This chapter describes the Power-On Self-Tes

Strany 106 - About Intel Server Control

Viglen SX220 User Guide 58 To remove the splash screen. <ESC> Power-On Self-Test (POST) Each time you turn on the system, POST starts running

Strany 107 - Managing Remote Servers

Viglen SX220 User Guide 511.. OOvveerrvviieeww Introduction This manual describes the Viglen SX220 system and the SCB2 motherboard. The motherbo

Strany 108 - Server Management Tools

Viglen SX220 User Guide 59Using BIOS Setup This section describes the BIOS Setup options. Use Setup to change the server configuration defaults. Y

Strany 109

Viglen SX220 User Guide 60 Main Menu You can make the following selections on the Main Menu itself. Use the submenus for other selections. Table 8:

Strany 110

Viglen SX220 User Guide 61Processor Retest Disabled Enabled Select yes for the BIOS to clear historical processor status and retest all processors on

Strany 111 - Client System Setup Utility

Viglen SX220 User Guide 62 Disabled present on a PCI add-in card installed in the slot In a 2U chassis, options for additional PCI slots PCI bus C wil

Strany 112 - DMI Explorer

Viglen SX220 User Guide 63Peripheral Configuration Submenu Table 18: Peripheral Configuration Submenu Features Feature Choices Description Serial Po

Strany 113 - Management Consoles

Viglen SX220 User Guide 64 Wake on LAN Disabled Enabled Legacy wake only: Determines the action of the system when a LAN wake up event occurs. Wake o

Strany 114 - • Local Direct

Viglen SX220 User Guide 65Server Menu Table 22: Server Menu Features Feature Choices Description System Management Press <Enter> Enters Sub

Strany 115 - Viglen SX220 User Guide 114

Viglen SX220 User Guide 66 COM2 2F8 IRQ3 management features. Make sure these values are identical to those of Serial Port A and B in the Peripheral

Strany 116 - Paging an Administrator

Viglen SX220 User Guide 67Table 27: Boot Device Priority Submenu Features Boot Priority Device Description 1st Boot Device Removable Attempts to

Strany 117

Viglen SX220 User Guide 68 Exit Menu You can make the following selections on the Exit Menu. Select an option using the up or down arrow keys. Press

Strany 118 - ISC Console Button Bar

Viglen SX220 User Guide 6 22.. CChhaassssiiss SSppeecciiffiiccaattiioonn The SX220 system consists of the following major components: • The chas

Strany 119 - Server Menu Options

Viglen SX220 User Guide 69When to Run the Adaptec SCSISelect Utility Use the SCSISelect utility to: • Change default values • Check and/or chang

Strany 120 - View Menu Options

Viglen SX220 User Guide 70 SCSI Disk Utilities Press <Enter> to view the SCSI Disk Utilities Menu. This menu allows you to format hard disks

Strany 121 - Viglen SX220 User Guide 120

Viglen SX220 User Guide 71DPC console runs on a client workstation. It communicates with a server by: • Accessing the server management capabiliti

Strany 122 - Initial System Startup

Viglen SX220 User Guide 72 Console go directly to the server, and the DPC Console displays the text that you would normally see on the server console.

Strany 123 - Checklist

Viglen SX220 User Guide 73What You Need to Do You can run the SSU directly from the SCB2 Server Software Kit CD-ROM by booting the server system to

Strany 124 - CAUTION!

Viglen SX220 User Guide 74 a. After creating set of three SSU diskettes from the CD: Insert the first SSU diskette in drive A, and press the reset b

Strany 125 - Monitoring POST

Viglen SX220 User Guide 75• Colour - this button lets you change the default colors associated with different items on the screen with predefined co

Strany 126 - Power Light Does Not Light

Viglen SX220 User Guide 76 OR • Highlight the task name, and click on OK. OR • Use the tab and arrow keys to highlight the desired button, and pr

Strany 127 - Viglen SX220 User Guide 126

Viglen SX220 User Guide 77Admin Password Button The ‘Admin Password’ button allows the user to set or change the administrative password used by bot

Strany 128 - Problems with Network

Viglen SX220 User Guide 78 • Lockout Timer—Set an interval that, if no activity takes place, it will drop the server into secure mode. • Secure Boo

Strany 129 - Viglen SX220 User Guide 128

Viglen SX220 User Guide 7Physical Specifications The SX220 chassis is designed as a 2U 19” Rackmount unit. The server will be supplied complete wi

Strany 130 - Diagnostic LEDs

Viglen SX220 User Guide 79SEL The SEL menu has the following options: • Properties: Displays information about the SEL. These fields are display

Strany 131 - Table 41 : POST Codes

Viglen SX220 User Guide 80 View The View menu has the following options: • FRU Info: Displays information about the FRU. These fields are display

Strany 132 - Viglen SX220 User Guide 131

Viglen SX220 User Guide 81SDR Manager Add-in The Sensor Data Record (SDR) Manager Add-in component allows users to view sensor data records stored i

Strany 133 - Viglen SX220 User Guide 132

Viglen SX220 User Guide 82 • Verify firmware code currently loaded versus an external hex file. • Update the BIOS from .bio or .uif files. The Sys

Strany 134 - G=Green, R=Red, A=Amber

Viglen SX220 User Guide 83• PCI records in non-volatile storage • Non-volatile emergency management port (EMP), platform event paging (PEP), and P

Strany 135 - Viglen SX220 User Guide 134

Viglen SX220 User Guide 84 Recovery Agent If the BMC firmware remote update fails, the server will reboot into the service partition and the recovery

Strany 136 - Viglen SX220 User Guide 135

Viglen SX220 User Guide 85Platform Event Manager Add-in The Platform Event Manager (PEM) provides an interface for configuring Platform Event Paging

Strany 137 - WARNING!

Viglen SX220 User Guide 86 Platform Event Paging Dialog This dialog allows you to configure the Platform Event Paging features. (See Figure 44) F

Strany 138 - Equipment Log

Viglen SX220 User Guide 87Help Topics The Help Topics menu has the following options: • Help Topics: Displays help information. Enable PEP Chec

Strany 139 - Viglen SX220 User Guide 138

Viglen SX220 User Guide 88 Figure 45: BMC LAN-Configuration Dialog File The File menu has the following options: • Save: Allows you to save th

Strany 140 - Current Usage

Viglen SX220 User Guide 8 Front Panel Controls and Indicators Figure 2: Front Panel Controls and Indicators A – NIC 1 activity LED I – Power/sleep

Strany 141 - (see note 2)

Viglen SX220 User Guide 89Help Topics Menu The Help Topics menu has the following options: • Help Topics: Displays help information. Enable LAN

Strany 142

Viglen SX220 User Guide 90 Gateway IP Address Enter the Logical or Internet Address of the router. The Gateway IP Address will only be saved when D

Strany 143 - Contacting Viglen

Viglen SX220 User Guide 91 Figure 46 : Platform Event Action Dialog File Menu The File menu has the following options: • Save: Allows you to sa

Strany 144 - Viglen SX220 User Guide 143

Viglen SX220 User Guide 92 Buttons • >>: Moves all the events from the enabled listbox to the disabled listbox. • >: Moves the selected

Strany 145 - Viglen SX220 User Guide 144

Viglen SX220 User Guide 93• Save: Allows you to save the configuration immediately. • Close: Allows you to close the Emergency Management Port d

Strany 146 - Viglen SX220 User Guide 145

Viglen SX220 User Guide 94 Modem Init String The Modem Init String string is transmitted every time the EMP initialises. The length of the paging st

Strany 147 - Viglen SX220 User Guide 146

Viglen SX220 User Guide 95Platform Event Paging With Platform Event Paging (PEP), your server can automatically dial up a paging service and page yo

Strany 148 - Viglen SX220 User Guide 147

Viglen SX220 User Guide 96 Software Updates Your system comes with preinstalled system BIOS and BMC firmware. When necessary, updates will be availa

Strany 149 - Viglen SX220 User Guide 148

Viglen SX220 User Guide 972. Print, review, and follow the instruction.rtf file (it supercedes any other instructions) 3. Label three blank floppy

Strany 150 - Viglen SX220 User Guide 149

Viglen SX220 User Guide 98 3. Disk 3 – SCB2 FRU/SDR update—Prompts you to choose the chassis type. You can choose to update the chassis information;

Komentáře k této Příručce

Žádné komentáře