Strany 1 - 470 Switch

A18558-002Intel® NetStructure™ 470 Switch User GuideIntel® NetStructure™470 SwitchUser Guide

Strany 2

4CHAPTER 1Intel® NetStructure™ 470T and 470F Switches User GuideConnection GuidelinesGeneral• The 470T switch is can auto-negotiate port duplex. It ca

Strany 3 - Contents

94CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideEdit an IEEE 802.1Q VLAN (ConfigureMembership)DescriptionUse this screen to change wh

Strany 4 - 5 Using Local Management

95Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuConfigure VLANEdit/Delete IEEE 802.1Q VLANEdit an IEEE 802.1Q VLAN (ConfigurePort Ta

Strany 5

96CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure VLAN ID for Untagged TrafficDescriptionUse this screen to set the switch up

Strany 6 - Intel Customer Support 146

97Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuConfigure a VLANGVRP/Ingress Filter SettingsNOTEFor GVRP to work, the port mustbe co

Strany 7 - Setting up the Intel

98CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure a Protocol-based VLANDescriptionVLAN operation mode: Changes the type of VL

Strany 8 - Switch Features

99Using Local ManagementCHAPTER 5Local ManagementAdd a Protocol-based VLANDescriptionVLAN Name: Assigns a name to the VLAN. The name can consist of an

Strany 9 - 470 Switch Setup

100CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideEdit/Delete a Protocol-based VLAN DescriptionUse this screen to select a VLAN, to e

Strany 10 - Connection Guidelines

101Using Local ManagementCHAPTER 5Local ManagementEdit a Protocol-based VLAN (ConfigureMembership)DescriptionUse this screen to identify which ports a

Strany 11 - Crossover UTP cable (100Mbps)

102CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideMonitor (Network Statistics)DescriptionSwitch overview: Displays an overview of all

Strany 12 - CHAPTER 1

103Using Local ManagementCHAPTER 5Local ManagementSwitch OverviewDescriptionThis screen provides an overview of activity on the switch—the traffic sen

Strany 13 - NetStructure™ 470T

5Setting Up the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 1470 Switch SetupCrossover UTP cable (100Mbps) Switch (MDI-X) Hub (MDI-X)

Strany 14 - Sample Configuration

104CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuidePort Traffic StatisticsDescriptionSelect port: Selects the range of ports to view. Y

Strany 15 - Broadcast Storm Control

105Using Local ManagementCHAPTER 5Local ManagementBytes sent: Displays the number of error-free bytes (octets) sent over thisport.Frames received: Dis

Strany 16 - Spanning Tree Protocol

106CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuidePort Error StatisticsDescriptionSelect port: Selects the range of ports to view. You

Strany 17 - Priority Tagging

107Using Local ManagementCHAPTER 5Local ManagementLate collision: Displays the number of collisions detected after theallowable detection period. This

Strany 18 - Link Aggregation

108CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuidePacket AnalysisDescriptionUse this screen to view a breakdown of the traffic receive

Strany 19 - Virtual LANs

109Using Local ManagementCHAPTER 5Local ManagementIGMP Snooping StatusDescriptionUse this screen to view the active multicast groups detected by the s

Strany 20 - Tag-based (IEEE 802.1Q) VLANs

110CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideBrowse Address TableDescriptionUse this screen to sort through the switch’s MAC addr

Strany 21 - Using the 470 Switch

111Using Local ManagementCHAPTER 5Local ManagementTotal addresses in table: Displays the total number of addresses learnedby the switch. This number i

Strany 22 - Protocol-based VLANs

112CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideVLAN and GVRP Status DescriptionThis screen is available only if there are active ta

Strany 23

113Using Local ManagementCHAPTER 5Local ManagementToolsDescriptionView switch traps and events (log): Displays events contained in theswitch’s interna

Strany 24

6CHAPTER 1Intel® NetStructure™ 470T and 470F Switches User Guide

Strany 25 - Using Intel

114CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideSwitch Event LogDescriptionUse this screen to view and navigate the switch’s log. Th

Strany 26 - Installing Intel Device View

115Using Local ManagementCHAPTER 5Local ManagementPing a DeviceDescriptionTarget IP address: Type the IP address of the device you want the switchto p

Strany 27 - Starting Intel Device View

116CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideUpload Configuration Image FileDescriptionUploads a configuration image file to a TF

Strany 28 - Using the Device Tree

117Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuSave SettingsSave SettingsDescriptionTo permanently save modified IP Settings, you

Strany 29 - Device Tree icons

118CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User Guide

Strany 30 - Losing contact with a switch

119Technical InformationAPPENDIXAppendixTechnicalInformationA119About the Configuration FileA configuration file is an ASCII text file that contains i

Strany 31 - Viewing RMON Information

120APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideSave Configuration FileYou can save the changes you make to the switch’s configuraton

Strany 32 - To view RMON statistics

121Technical InformationAPPENDIXAppendixSample Configuration FileThe following is an example of a configuration file. For more explanationand keyword

Strany 33 - Device Manager

122APPENDIXIntel® NetStructure™ 470T and 470F Switches User Guide###### Port Level Configuration ############################################### Sta

Strany 34

123Technical InformationAPPENDIXAppendix#### Configure a Protocol Based VLAN ############################################## proto_vlan_list={(Vlan,Pro

Strany 35 - Using Management Screens

Using the Intel®NetStructure™ 470Tand 470F Switches27OverviewChapter 2 provides an overview for using the Intel® NetStructure™ 470Tand 470F Switches w

Strany 36

124APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideBOOT MenuDescriptionThe BOOT Menu provides a quick way to troubleshoot some of the ba

Strany 37 - Web Device Manager

125Technical InformationAPPENDIXAppendixUpdate BOOT PROM1 Copy E470PROM.tfp, E470RUN, tfp, and E470.cfg from the ziparchive into a directory that i

Strany 38 - Configuring a Port

126APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideUpdate FirmwareThe firmware can be updated after the Boot PROM has been successfullyu

Strany 39 - Managing User Accounts

127Technical InformationAPPENDIXAppendixList of Factory Defaults• Software upgrade mode: Network• TFTP Server Address: 0.0.0.0• Load configuration fil

Strany 40 - To delete a user account

128APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideTroubleshooting/FAQsHow can I set the speed or duplex on individual ports?Normally th

Strany 41 - Configuring VLANs

129Technical InformationAPPENDIXAppendixI keep getting an intermittent loss of link (or data is notbeing transmitted). Why?• You may be using the wron

Strany 42 - Port-based VLAN

130APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideRegulatory InformationFCC Part 15 Compliance StatementThis product has been tested an

Strany 43 - Tag-based VLAN

131Technical InformationAPPENDIXAppendixAVERTISSEMENTLe système a été conçu pour fonctionner dans un cadre de travailnormal. L’emplacement choisi doit

Strany 44 - CHAPTER 4

132APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideWichtige Sicherheitshinweise1. Bitte lesen Sie sich diese Hinweise sorgfältig durch.2

Strany 45

133Technical InformationAPPENDIXAppendixLimited Hardware WarrantyIntel warrants to the original owner that the hardware product delivered in this pack

Strany 46 - Protocol-based VLAN

8CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuideSample ConfigurationThe following example illustrates how the 470T and 470F switches c

Strany 47 - Static MAC Addresses

134APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideLimited Hardware Warranty (Europe only)Intel warrants to the original owner that the

Strany 48

135Technical InformationAPPENDIXAppendixLimitation de garantie du matériel (Europe)Intel garantit au propriétaire original que le produit matériel liv

Strany 49 - Setting Up Priority Tagging

136APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideGaranzia limitata sull’hardware (valida solo in Europa)Intel garantisce al proprietar

Strany 50 - Trap Receivers

137Technical InformationAPPENDIXAppendixBeschränkte Hardwaregarantie (Nur für Europa)Intel garantiert dem ursprünglichen Eigentümer, daß die in diesem

Strany 51 - Monitoring Switch Activity

138APPENDIXIntel® NetStructure™ 470T and 470F Switches User GuideGarantía limitada de hardware (sólo para Europa)Intel garantiza al propietario origin

Strany 52

139IntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T and

Strany 53 - Updating Switch Firmware

140INDEXIntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T

Strany 54 - Logging Out

141IntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T and

Strany 55 - Management

142INDEXIntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T

Strany 56 - Logon Screen

143IntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T and

Strany 57 - Navigation

9Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 SwitchFlow ControlDuring heavy network activity, the switch’s port buffer

Strany 58 - Main Menu (Top Screen)

144INDEXIntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T

Strany 59 - Configure Device

145IntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T and

Strany 60 - IP Settings

146INDEXIntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T

Strany 61 - Port Settings

147IntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T and

Strany 62 - Priority

148INDEXIntelIntelIntelIntelIntel®®®®® NetStructure NetStructure NetStructure NetStructure NetStructure     470T and 470F Switches User Guide470T

Strany 63

A18558-002

Strany 64

10CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuidePrimary Path from Client A to Server B: Switch A –> Switch CThe switch checks the

Strany 65 - Switch Settings

11Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 SwitchIn this example, Client A can communicate with Server B over two d

Strany 66

12CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuideAlthough there are eight priority levels, the 470 switches can only put apacket into

Strany 67

13Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 Switch Guidelines• The switch treats aggregated links as a single port.

Strany 68

Copyright © 2001, Intel Corporation. All rights reserved.Intel Corporation, 5200 NE Elam Young Parkway, Hillsboro OR 97124-6497Intel Corporation assum

Strany 69

14CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuidePort-based VLANsPort-based VLANs are the simplest and most common form of VLAN. In ap

Strany 70 - Forwarding and Filtering

15Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 SwitchThe 802.1Q VLAN works by using a tag added to the Ethernet frames.

Strany 71 - Configure IGMP Snooping

16CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuideProtocol-based VLANsIn a protocol-based VLAN, traffic is bridged through specified po

Strany 72

17Using the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 2Using the 470 SwitchSpanning Tree Protocol and VLANsThe 470 switches support the Spann

Strany 73 - Configure Port Security

18CHAPTER 2Intel® NetStructure™ 470T and 470F Switches User GuideGARP (Generic Attribute Registration Protocol) is defined by the IEEE802.1D (1998 Edi

Strany 74

Using Intel® DeviceView3OverviewIntel® Device View allows you to manage Intel NetStructure™ 470T and470F switches and other supported Intel networkin

Strany 75

20CHAPTER 3Intel® NetStructure™ 470T and 470F Switches User GuideInstalling Intel Device ViewBefore you install Intel Device View, make sure your PC m

Strany 76 - To modify a multicast filter

21Intel Device ViewCHAPTER 3Intel® Device ViewStarting Intel Device ViewInstall either the Windows or Web version of Intel Device View.Windows* versio

Strany 77 - Port Mirroring

22CHAPTER 3Intel® NetStructure™ 470T and 470F Switches User GuideInstalling a New SwitchAfter you install a new switch on your network, you can use th

Strany 78

23Intel Device ViewCHAPTER 3Intel® Device ViewDifferent states of the 470 switches are represented by icons in the DeviceTree.Device Tree iconsDevice

Strany 79 - Broadcast Storm Control

iIntel® NetStructure     470T and 470F Switches User GuideCONTENTSiContents1 Setting up the Intel® NetStructure™ 470T and470F SwitchesOverview .

Strany 80 - Configure Management Menu

24CHAPTER 3Intel® NetStructure™ 470T and 470F Switches User GuideTo refresh the Device TreeRefreshing the Device Tree updates it to show any newly dis

Strany 81

25Intel Device ViewCHAPTER 3Intel® Device ViewManaging a SwitchTo manage a 470T or 470F switch, double-click the switch icon in theDevice Tree. In the

Strany 82 - Administer User Accounts

26CHAPTER 3Intel® NetStructure™ 470T and 470F Switches User Guide• Group 1 (Statistics): Monitors utilization and error statistics for eachnetwork seg

Strany 83

Using the WebDevice Manager427OverviewWith the Web Device Manager, which is built into the Intel® NetStructure™470T and 470F Switches, you can use a W

Strany 84

28CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideNOTEThe default IP address for theswitch is 192.0.2.1. To accessthe switch with the d

Strany 85

29Using the Web Device ManagerCHAPTER 4Web Device ManagerClick a menu to viewavailable options.2 In the menu, click an option. The corresponding scree

Strany 86 - Define IP Access List

30CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideIf the option you selected allows you to configure or monitor a specific port,you can

Strany 87

31Using the Web Device ManagerCHAPTER 4Web Device ManagerConfiguring the Switch’s IP SettingsNote: You must select Manual in the IP Assignment Method

Strany 88 - Reset and Console Options

32CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideConfiguring a PortYou can use the Web Device Manager to enable or disable a port, and

Strany 89 - Configure VLAN Operation Mode

33Using the Web Device ManagerCHAPTER 4Web Device ManagerManaging User AccountsCreate user accounts to give specific users read or write access to the

Strany 90

iiCONTENTSIntel® NetStructure     470T and 470F Switches User Guide4 Using the Web Device ManagerOverview ...

Strany 91 - Add a Port-based VLAN

34CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User Guide6 In the Access Level box, click an access level. An administrator canview all settin

Strany 92 - Edit/Delete a Port-based VLAN

35Using the Web Device ManagerCHAPTER 4Web Device ManagerConfiguring VLANsVLANs provide a way to create a logical network grouping without regardto ph

Strany 93

36CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuidePort-based VLANYou configure a port-based VLAN by creating the VLAN and then addingpa

Strany 94 - Configure 802.1Q VLANs

37Using the Web Device ManagerCHAPTER 4Web Device ManagerTag-based VLANYou configure a tag-based VLAN by configuring port membership andingress/egress

Strany 95 - Port Membership)

38CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User Guide2 Configure ports for egress (outbound) tagging. • Ensure that the VLAN Name field di

Strany 96

39Using the Web Device ManagerCHAPTER 4Web Device ManagerOptions include:• Default Port VID: Sets the PVID to be assigned to untagged trafficon a give

Strany 97 - Configuring 802.1Q VLANs

40CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideProtocol-based VLANYou configure a protocol-based VLAN by creating the VLAN and thena

Strany 98

41Using the Web Device ManagerCHAPTER 4Web Device ManagerLink AggregationOn the Web Device Manager’s switch faceplate graphic, a link aggregationis sh

Strany 99 - Edit/Delete an 802.1Q VLAN

42CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User Guide• You can manually add MAC addresses to the table. These are calledstatic addresses,

Strany 100 - Membership)

43Using the Web Device ManagerCHAPTER 4Web Device ManagerSetting Up Priority TaggingWith priority tagging, you can specify a priority value for traffi

Strany 101 - Port Tagging)

iiiIntel® NetStructure     470T and 470F Switches User GuideCONTENTSConfigure IGMP Snooping ...65Conf

Strany 102 - Description

44CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideConfiguring Community Strings andTrap ReceiversA trap receiver is a computer on the n

Strany 103

45Using the Web Device ManagerCHAPTER 4Web Device ManagerMonitoring Switch ActivityWith the Web Device Manager you can view traffic, utilization, and

Strany 104

46CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User GuideViewing/Changing Switch InformationYou can view general information about the switch,

Strany 105 - Add a Protocol-based VLAN

47Using the Web Device ManagerCHAPTER 4Web Device ManagerUpdating Switch FirmwareOn the Update Firmware screen you can set up the switch to update its

Strany 106

48CHAPTER 4Intel® NetStructure™ 470T and 470F Switches User Guide5 In the File Name box, type the name of the firmware file.6 Click Submit.The switch

Strany 107

49Using Local ManagementCHAPTER 5Local ManagementUsing LocalManagement5OverviewAnother way to configure the switch is through the Local Managementinte

Strany 108 - Monitor (Network Statistics)

50CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideTo useTelnet1 Open a Telnet application. In Windows 98 or Windows NT*, selectRun from

Strany 109 - Switch Overview

51Using Local ManagementCHAPTER 5Local ManagementNavigationThe console menus provide a basic interface for configuring switch options.For navigation t

Strany 110 - Port Traffic Statistics

52CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideMain Menu (Top Screen)DescriptionThe Main Menu is the starting point for all other Lo

Strany 111 - Local Management

53Using Local ManagementCHAPTER 5Local ManagementConfigure DeviceDescriptionIP settings: Configures the switch’s IP address, subnet mask, and defaultg

Strany 112 - Port Error Statistics

ivCONTENTSIntel® NetStructure     470T and 470F Switches User GuideMonitor (Network Statistics) ...102S

Strany 113

54CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideIP SettingsDescriptionSwitch MAC address: Displays the unique hardware address assign

Strany 114 - Packet Analysis

55Using Local ManagementCHAPTER 5Local ManagementPort SettingsDescriptionConfigure ports: Selects a range of ports to configure (press z).State: Disab

Strany 115 - IGMP Snooping Status

56CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideFlow ControlDuring times of heavy network activity, the switch’s port buffers canrece

Strany 116 - Browse Address Table

57Using Local ManagementCHAPTER 5Local ManagementConfigure GBIC Ports (470T only)DescriptionPort 7- and 8-GBIC: Displays the type of GBIC installed on

Strany 117

58CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuidePriority TaggingDescriptionWith priority tagging, you can specify a priority value fo

Strany 118 - VLAN and GVRP Status

59Using Local ManagementCHAPTER 5Local ManagementSwitch SettingsDescriptionName: Assigns a name to the switch, up to 40 characters long.Location: Assi

Strany 119

60CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure Advanced Switch SettingsDescriptionHead of Line (HOL) blocking prevention:

Strany 120 - Switch Event Log

61Using Local ManagementCHAPTER 5Local ManagementConfigure Spanning Tree ProtocolDescriptionThe IEEE 802.1D Spanning Tree Protocol specification preve

Strany 121 - Ping a Device

62CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideHello time: Displays the time between transmissions of configurationBPDUs (Bridge Pro

Strany 122

63Using Local ManagementCHAPTER 5Local ManagementConfigure Spanning Tree for PortsDescriptionPort: Identifies port numbers; select the port you want t

Strany 123 - Save Settings

Setting up the Intel®NetStructure™ 470Tand 470F Switches11OverviewThis guide provides information on configuring and managing the Intel®NetStructure™

Strany 124 - CHAPTER 5

64CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideForwarding and FilteringDescriptionLock address table: Determines if the table learns

Strany 125 - Information

65Using Local ManagementCHAPTER 5Local ManagementConfigure IGMP SnoopingDescriptionIGMP snooping (Internet Group Management Protocol) allows the switc

Strany 126 - Load Configuration File

66CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure Static MAC AddressesDescriptionStatic MAC addresses are MAC addresses that

Strany 127 - Sample Configuration File

67Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuConfigure DeviceForwarding and FilteringConfigure Port SecurityConfigure Port Securi

Strany 128 - APPENDIX

68CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure MAC Address FilteringDescriptionMAC address filtering allows the switch to

Strany 129 - Appendix

69Using Local ManagementCHAPTER 5Local ManagementConfigure Ethernet Multicast FilteringDescriptionYou can use Ethernet multicast filters to define whi

Strany 130 - BOOT Menu

70CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideEthernet Multicast Filtering (Ports)DescriptionAction: Blocks or forwards traffic to

Strany 131 - Update BOOT PROM

71Using Local ManagementCHAPTER 5Local ManagementPort MirroringDescriptionPort mirroring is a diagnostic tool you can use to send a copy of the goodEt

Strany 132 - Update Firmware

72CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideLink AggregationDescriptionLink aggregation is a way of combining ports on the switch

Strany 133 - List of Factory Defaults

73Using Local ManagementCHAPTER 5Local Management Broadcast Storm ControlDescriptionYou can use broadcast storm control to filter out broadcasts from

Strany 134 - Troubleshooting/FAQs

2CHAPTER 1Intel® NetStructure™ 470T and 470F Switches User GuideSwitch FeaturesThese are the major features of the 470 switches.• 100/1000 Base-T auto

Strany 135 - Locating MIB files

74CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure Management MenuDescriptionConfigure community strings & trap receivers:

Strany 136 - Warnings

75Using Local ManagementCHAPTER 5Local ManagementCommunity Strings & Trap ReceiversDescriptionUse this screen to send alerts to PCs with SNMP mana

Strany 137

76CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideAdminister User AccountsDescriptionAdd Users/Change PasswordsUsername: By default, no

Strany 138 - Wichtige Sicherheitshinweise

77Using Local ManagementCHAPTER 5Local ManagementAccess level: Establishes a user’s access rights (press z).Administrators can make any changes to Loc

Strany 139 - Limited Hardware Warranty

78CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideManaging User AccountsSystem Administrators can create up to three user accounts for

Strany 140

79Using Local ManagementCHAPTER 5Local Management6 To save the new password, press T to select SAVE CHANGES(below the Confirm new password field) and

Strany 141

80CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideDefine IP Access ListDescriptionUsers with IP addresses defined on the access list ca

Strany 142

81Using Local ManagementCHAPTER 5Local ManagementUpdate Firmware and Config Files DescriptionSoftware update mode: Choose to update switch firmware o

Strany 143

82CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideReset and Console OptionsDescriptionReset OptionsReboot switch: Reboots the switch. I

Strany 144

83Using Local ManagementCHAPTER 5Local ManagementConfigure VLAN Operation Mode DescriptionUse this screen to activate or change the type of VLAN oper

Strany 145 - I N D E X

3Setting Up the Intel® NetStructure™ 470T and 470F SwitchesCHAPTER 1470 Switch SetupLEDsThe LEDs to the left of the ports indicate port status, indivi

Strany 146

84CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideLOCATIONMain MenuConfigure VLANPort-based VLANsDescriptionPort-based VLANs are the si

Strany 147

85Using Local ManagementCHAPTER 5Local ManagementAdd a Port-based VLAN DescriptionVLAN Name: Assigns a name to the VLAN. Names can consist of anychara

Strany 148

86CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideTo create a port-based VLAN1 On the Main Menu, select Configure VLAN.Note: Make sure

Strany 149

87Using Local ManagementCHAPTER 5Local ManagementChange Port Membership in a VLAN DescriptionThis screen is similar to the VLAN creation screen. You

Strany 150

88CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideConfigure 802.1Q VLANs DescriptionVLAN operation mode: Changes the type of VLAN oper

Strany 151

89Using Local ManagementCHAPTER 5Local ManagementAdd an IEEE 802.1Q VLAN (ConfigurePort Membership)DescriptionVLAN Name: Assigns a name to the VLAN. T

Strany 152 - Intel Customer Support

90CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideAdd an IEEE 802.1Q VLAN (ConfigurePort Tagging)DescriptionVLAN Name: Displays the VLA

Strany 153

91Using Local ManagementCHAPTER 5Local ManagementConfiguring 802.1Q VLANsSetting up an 802.1Q VLAN is a three-step process. First, create a VLANon the

Strany 154

92CHAPTER 5Intel® NetStructure™ 470T and 470F Switches User GuideStep 3: Configure VLAN for untagged devicesEven if the device attached to the switch

Strany 155 - A18558-002

93Using Local ManagementCHAPTER 5Local ManagementLOCATIONMain MenuConfigure VLANEdit/Delete an 802.1Q VLANEdit/Delete an 802.1Q VLAN DescriptionUse t