Intel SR2500 Datový list Strana 31

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 115
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 30
Intel® Server System SR2500AL Power Sub-System
Revision – 1.00
Intel order number D31980-004
19
2.11 Power Supply Status LED
Each power supply module will have a single bi-color LED to indicate power supply status. The
LED operation is defined below.
Table 12. LED Indicators
Power Supply Condition Bi-Color LED
No AC power to all power supplies
OFF
No AC power to this PSU only (for 1+1 configuration)
or
Power supply critical event causing a shutdown:
failure, fuse blown (1+1 only), OCP, OVP, Fan Failed
AMBER
Power supply warning events where the power supply continues to
operate: high temp, high power, high current, slow fan.
1Hz Blink AMBER
AC present / Only 5VSB on (PS Off)
1Hz Blink GREEN
Output ON and OK
GREEN
The LED is visible on the rear panel of each installed power supply module.
Zobrazit stránku 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 114 115

Komentáře k této Příručce

Žádné komentáře